Cisco: factory reset a phone

Read this first. If ArmourTel supplied the phone pre-configured, particularly an MPP model such as a 78xx or 88xx, a factory reset will remove its configuration and it will not come back on its own. Raise a ticket rather than resetting.

SPA series

  1. From the phone: press the Setup button, then Factory Reset, and confirm.
  2. Key sequence: on many SPA models you can enter **** (four asterisks) followed by 73738#, then press 1 to confirm.
  3. From the web page: log in as administrator and look under Admin → Factory Reset, or Voice → Provisioning → Factory Reset.

MPP series

  1. Press Settings, then Admin Settings → Reset Settings or Factory Reset.
  2. Enter the administrator password when prompted.
  3. Confirm and allow the phone to restart. It may take several minutes to reboot.

After a reset

An SPA phone returns to its factory web credentials and will need its line configured again. An MPP phone will try to contact its provisioning server; if it was supplied by ArmourTel, tell us so we can re-provision it.

ArmourTel · www.armour.tel · support@armour.tel